Industrial DIN Rail Power Supplies
SerialComm offer industrial-grade regulated DIN rail power supplies in 5V, 12V, 24V and 48V configurations in a full range or power outputs. They include free worldwide shipping from NJ and CA and same day express at low prices. Our offered power supplies can be used for any application whether it is for commercial, industrial or critical. If you need protection, reliability, and power efficiency at low prices we have the solution and we back our products with a 30 day risk-free money back guarantee and 5 year replacement warranty. SerialComm is committed to providing the best customer support possible with 24 hour telephone, live chat and email support. Our converters provide a safe and easy solution for your data communication requirements.
-
Mean Well 10W Industrial DIN Rail Power Supplies
Model: P-MDR-10-5 | P-MDR-10-12 | P-MDR-10-24 Price: $32.95
Data SheetP-MDR-10-5 P-MDR-10-12 P-MDR-10-24 Output Voltage: 5V DC 12V DC 24V DC Max Power: 10 Watts 10 Watts 10 Watts Output Max Current: 2.00 Amps 0.84 Amps 0.42 Amps Input Voltage: 85-264 VAC 85-264 VAC 85-264 VAC - Universal AC Input (Full Range)
- 100% Full Load Burn-in Test
- Isolated Plastic Enclosure
- Fan-less Design, Cooling by Free Air Convection
- Can Be Installed on DIN Rail TS35 / 7.5 or 15
- Operating Temperature Range: -4ºF to 158ºF (-20ºC to 70ºC)
- Short Circuit / Overload / Over Voltage Protections
- UL508 and TUV EN 62368-1 Safety Approvals
-
Mean Well 20W Industrial DIN Rail Power Supplies
Model: P-MDR-20-5 | P-MDR-20-12 | P-MDR-20-24 Price: $36.95
Data SheetP-MDR-20-5 P-MDR-20-12 P-MDR-20-24 Output Voltage: 5V DC 12V DC 24V DC Max Power: 15 Watts 25 Watts 24 Watts Output Max Current: 3.00 Amps 1.67 Amps 1.00 Amps Input Voltage: 85-264 VAC 85-264 VAC 85-264 VAC - Universal AC Input (Full Range)
- 100% Full Load Burn-in Test
- Isolated Plastic Enclosure
- Fan-less Design, Cooling by Free Air Convection
- Can Be Installed on DIN Rail TS35 / 7.5 or 15
- Operating Temperature Range: -4ºF to 158ºF (-20ºC to 70ºC)
- Short Circuit / Overload / Over Voltage Protections
- UL508 and TUV EN 62368-1 Safety Approvals
-
Mean Well 40W Industrial DIN Rail Power Supplies
Model: P-MDR-40-5 | P-MDR-40-12 | P-MDR-40-24 | P-MDR-40-48 Price: $45.95
Data SheetP-MDR-40-5 P-MDR-40-12 P-MDR-40-24 P-MDR-40-48 Output Voltage: 5V DC 12V DC 24V DC 48V DC Max Power: 30 Watts 40 Watts 40 Watts 39 Watts Output Max Current: 6.00 Amps 3.33 Amps 1.7 Amps 0.83 Amps Input Voltage: 85-264 VAC 85-264 VAC 85-264 VAC 85-264 VAC - Universal AC Input (Full Range)
- 100% Full Load Burn-in Test
- Isolated Plastic Enclosure
- Fan-less Design, Cooling by Free Air Convection
- Can Be Installed on DIN Rail TS35 / 7.5 or 15
- Operating Temperature Range: -4ºF to 158ºF (-20ºC to 70ºC)
- Short Circuit / Overload / Over Voltage Protections
- UL508 and TUV EN 62368-1 Safety Approvals
-
Mean Well 75W Industrial DIN Rail Power Supplies
Model: P-SDR-75-12 | P-SDR-75-24 | P-SDR-75-48 Price: $63.95
Data SheetP-SDR-75-12 P-SDR-75-24 P-SDR-75-48 Output Voltage: 12V DC 24V DC 48V DC Max Power: 75 Watts 76 Watts 76 Watts Output Max Current: 9.37 Amps 3.20 Amps 2.34 Amps Input Voltage: 85-264 VAC 85-264 VAC 85-264 VAC - Universal AC Input (Full Range)
- 100% Full Load Burn-in Test
- Isolated Metal Enclosure
- High 90% Efficiency and Low Power Dissipation
- 150% Peak Load Capacity
- Fan-less Design, Cooling by Free Air Convection
- Can Be Installed on DIN Rail TS35 / 7.5 or 15
- Operating Temperature Range: -4ºF to 158ºF (-20ºC to 70ºC)
- Short Circuit / Overload / Over Voltage / Over Temp. Protections
- UL508 and TUV EN 62368-1 Safety Approvals
- EN61000-6-2 and EN50082-2 Industrial Immunity Level
-
Mean Well 120W Industrial DIN Rail Power Supplies
Model: P-SDR-120-12 | P-SDR-120-24 | P-SDR-120-48 Price: $85.95
Data SheetP-SDR-120-12 P-SDR-120-24 P-SDR-120-48 Output Voltage: 12V DC 24V DC 24V DC Max Power: 120 Watts 120 Watts 120 Watts Output Max Current: 10.00 Amps 5.00 Amps 2.50 Amps Input Voltage: 85-264 VAC 85-264 VAC 85-264 VAC - Universal AC Input (Full Range)
- 100% Full Load Burn-in Test
- Isolated Metal Enclosure
- High 90% Efficiency and Low Power Dissipation
- 150% Peak Load Capacity
- Fan-less Design, Cooling by Free Air Convection
- Can Be Installed on DIN Rail TS35 / 7.5 or 15
- Operating Temperature Range: -13ºF to 158ºF (-25ºC to 70ºC)
- Short Circuit / Overload / Over Voltage / Over Temp. Protections
- UL508 and TUV EN 62368-1 Safety Approvals
- EN61000-6-2 and EN50082-2 Industrial Immunity Level
-
240W Mean Well Industrial DIN Rail Power Supplies
Model: P-NDR-240-24 | P-NDR-240-48 Price: $94.95
Data SheetP-NDR-240-24 P-NDR-240-48 Output Voltage: 24V DC 48V DC Max Power: 240 Watts 240 Watts Output Max Current: 10.00 Amps 5.00 Amps Input Voltage: 90-264 VAC 90-264 VAC - Universal AC Input (Full Range)
- 100% Full Load Burn-in Test
- Isolated Metal Enclosure
- High 90% Efficiency and Low Power Dissipation
- 150% Peak Load Capacity
- Fan-less Design, Cooling by Free Air Convection
- Can Be Installed on DIN Rail TS35 / 7.5 or 15
- Operating Temperature Range: -4ºF to 158ºF (-20ºC to 70ºC)
- Short Circuit / Overload / Over Voltage / Over Temp. Protections
- UL508 and TUV EN 62368-1 Safety Approvals
- EN61000-6-2 and EN50082-2 Industrial Immunity Level